5.1.4
Format Track–50H
This command writes the desired head and cylinder of the selected drive with
an FFh pattern. To remain host backward compatible, the card expects a
sector buffer of data from the host to follow the command with the same
protocol as the Write Sector(s) command, although the card does not use the
information in the buffer. If LBA=1 then the number of sectors to format is
taken from the Sec Cnt register (0=256).
Note: The Format Track command in Table 41 is no longer recommended. The
command is supported to guarantee backward compatibility.
Table 41: Format Track
5.1.5
Identify Device–ECH
The Identify Drive command enables the host to receive parameter
information from a CompactFlash Memory Card. This command has the same
protocol as the Read Sector(s) command. The parameter words in the buffer
have the arrangement and meanings defined in Table 5-8. All reserved bits or
words are “0”.
Table 42: Identify Device
Table 43 defines each field in the Identify Device Information.
Table 43: Identify Device Information
Word
Address
Default
Value
Total
Bytes
Data Field Type Information
0 848Ah 2 General configuration bit-significant information
1 XXXXh 2 Default number of cylinders
2 0000h 2 Reserved
3 XXXXh 2 Default number of heads
4 0000h 2 Number of unformatted bytes per track
5 0000h 2 Number of unformatted bytes per sector
6 XXXXh 2 Default number of sectors per track