SanDisk Industrial Grade CompactFlash 5000 Product Manual
© 2007 SanDisk® Corporation 60 July 2007
registers contain the cylinder, head, and sector number of the last sector
verified.
If an error occurs, the Verify command terminates at the sector where the
error occurs. The Command Block registers contain the cylinder, head and
sector number of the sector where the error occurred. The Sector Count
Register contains the number of sectors not yet verified.
Table 56: Read Verify Sector(s)
5.1.15
Recalibrate–1XH
This command is effectively a NOP command to the CompactFlash Memory
Card and is provided for compatibility purposes. After this command is
executed the Cyl High and Cyl Low as well as the Head number will be 0 and
Sec Num will be 1 if LBA=0 and 0 if LBA=1 (i.e., the first block in LBA is 0
while CHS mode the sector number starts at 1).
Table 57:
Recalibrate
5.1.16
Request Sense–03H
This command requests an extended error code after a command ends with an
error.
Table 58:
Request Sense